Choosing Combustible Gas Alarm Controller(JH-FII, JH-FD, JH-FK) for 4-20mA Detector Systems
  • Home
  • news
  • Choosing Combustible Gas Alarm Controller(JH-FII, JH-FD, JH-FK) for 4-20mA Detector Systems

Choosing Combustible Gas Alarm Controller(JH-FII, JH-FD, JH-FK) for 4-20mA Detector Systems

November 17, 2026

The Combustible Gas Alarm Controller (JH-FII, JH-FD, JH-FK) fits non-explosion-proof control rooms and control centers that collect 4-20mA signals from point-type combustible gas detectors. Check detector signal, channel count, alarm outputs, installation space, and operating conditions before ordering.

Illustration: Choosing Combustible Gas Alarm Controller(JH-FII, JH-FD, JH-FK) for 4-20mA Detector Systems
Illustration for reference; see the product page for actual photos and specifications.

The Combustible Gas Alarm Controller (JH-FII, JH-FD, JH-FK) is suited to non-explosion-proof places such as fire control rooms and control centers. We use it with point-type combustible gas detectors that provide 4-20mA signals. The controller collects gas concentration data and outputs alarm and control signals when the set alarm value is reached.

Start with the detector signal and channel count

Choose this controller when the connected point-type combustible gas detectors use 4-20mA communication and the project needs 1-2 channels. This signal match is the first purchase check because the controller is designed to collect concentration data through 4-20mA inputs.

The controller can connect with DCS and fire graphics systems. Its outputs can also start external equipment such as exhaust fans and solenoid valves, allowing the control arrangement to respond when an alarm value is reached.

Match the alarm and control functions to the site

The controller provides high and low limit alarms and fault alarms. It has two groups of relay outputs, rated at 1A 220VAC, for linkage with external equipment. It also supports RS485/Modbus RTU signals for connection to upper-level systems such as computers.

Alarm status hold keeps an alarm condition available for review. The alarm record storage and query function holds up to 1000 records, which suits projects that need a local history of alarm events.

Check the installation environment and enclosure space

This controller is wall mounted and has overall dimensions of 264×86×324mm. Measure the available wall area and cable routing space against these dimensions before placing the order.

The controller is intended for a non-explosion-proof installation location. The detected gas risk may be combustible, but the controller location still needs to match the intended installation environment.

Review the operating and power requirements

The operating voltage is 220V AC±15%. Backup power uses 12V DC/1.3Ah×2, and power consumption is ≤10W. The operating temperature range is -10℃~55℃, with operating humidity of ≤95%RH (Non-condensing).

The LCD display shows the controller information, while concentration units include %LEL, ppm, %VOL, and mg/m³. Confirm which unit and alarm values your monitoring plan requires before final configuration.

What to weigh

Detector interface4-20mA point-type combustible gas detector signals
Channel requirement1-2 detector channels
Installation settingnon-explosion-proof fire control room or control center
Linkage needstwo relay output groups and RS485/Modbus RTU communication
Site conditions220V AC±15%, wall mounting, -10℃~55℃ operation

Your shortlist

Combustible Gas Alarm Controller (JH-FII, JH-FD, JH-FK)Choose for 1-2 channel, 4-20mA detector systems in non-explosion-proof control rooms or control centers.

Which project should choose this controller?

Choose the Combustible Gas Alarm Controller (JH-FII, JH-FD, JH-FK) for a wall-mounted control-room or control-center installation with 1-2 point-type combustible gas detector channels, 4-20mA signals, local alarm handling, relay linkage, and upper-level system communication. The fit depends on those signal, channel, location, and power conditions.

For the product page and application details, see our Combustible Gas Alarm Controller (JH-FII, JH-FD, JH-FK). Send the detector signal type, channel requirement, installation dimensions, and intended external linkages when requesting a configuration review.

The company

Jiangsu Jihua Electronic Technology Co., Ltd

Jiangsu Jihua Electronic Technology Co., Ltd. was established in 2007. It is a national high-tech enterprise specializing in the research and development, production, sales and service of gas and dust concentration detection alarm and environmental monitoring equipment. The products are mainly used in many fields such as petroleum, chemical industry, gas, medicine, metallurgy, machinery, factories and mines, grain processing, environmental monitoring, etc.…

About Us ↗Visit company website ↗
Get Your Custom Detector Today!
Fill out the form below and our team will help you choose the perfect Detector for your project.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.