The JH-D is a single-circuit, non-explosion-proof wall-mounted alarm for real-time gas concentration display, audible and visual alarms, and external equipment links. It suits sites using 220V AC that need configurable gas sensing, 4-20mA or RS485 communication, and a 225 × 70 × 255 mm enclosure. Confirm the target gas, measuring range, mounting space, and area classification before ordering.
Area classification and wall-mounting conditions: confirm that a non-explosion-proof, single-circuit detector fits the installation and that the 225 × 70 × 255 mm enclosure can be mounted with usable display and cable access.
Gas, measuring range, and sensor principle: specify the target gas and required range so the sensor selection can be matched to electrochemical, laser, infrared, thermal conductivity, PID, or another suitable principle.
Control-system integration: match 4-20mA, RS485 Modbus RTU, passive contacts, and the audible/visual alarm interface to the receiving equipment and required external response.
Operating conditions and power: check 220V AC supply, -20°C to 50°C operating temperature, 10% to 95% RH non-condensing humidity, and maximum power consumption below 12W.
A wall mounted gas detector Manufacturer should help you match the detector to the gas, installation area, control system, and alarm response you need. Our JH-D Gas Detection Alarm (Standalone) is made for industrial single-circuit monitoring where the unit displays gas concentration and can trigger local or external responses.
JH-D is an industrial non-explosion-proof wall-mounted gas detector. That specification should be the first purchasing check. It suits an installation where a non-explosion-proof detector is acceptable. If the mounting location requires explosion-proof equipment, choose a configuration that meets that requirement instead of treating the JH-D as a universal gas detector.
The enclosure measures 225 × 70 × 255 mm. Measure the available wall area, cable access, and viewing position before confirming the mounting point. In a plant room, the 4.3-inch high-definition color screen shows real-time concentration, alarm, time, storage, and other information at the detector. Keep the display visible to the people who need to read the local condition during routine checks.
JH-D can be configured for toxic gases, O₂, CO₂, TVOC, and other gases through sensor selection. Its measuring range is also configurable by sensor selection, so include the gas name and required range in your order information.
Our plug-in sensor design connects different sensor components for different gas objects. This suits facilities monitoring different gases across separate areas and needing a detector format that supports sensor replacement and later maintenance. Send the gas name, expected concentration range, and installation area so we can match the sensor selection to the application.
The available detection principles include electrochemical, laser, infrared, thermal conductivity, and PID. The appropriate principle depends on the selected gas and sensor. Ask us to confirm the sensor principle and measuring range for the gas you need to detect instead of selecting by the enclosure alone.
JH-D provides two communication paths: a 4-20mA current loop and RS485 using Modbus RTU. Choose the interface that matches the receiving equipment already installed at your site. A 4-20mA connection suits an analog input, while RS485 suits a digital monitoring network that uses Modbus RTU.
The alarm also has one set of passive contacts and one set of audible/visual alarm interface. When the gas concentration exceeds the set alarm value, the unit emits sound and light alarm signals and outputs switch signals. These outputs can link to external equipment such as sound and light alarms, exhaust opening, or valve closing.
Picture a detector mounted near a process area and connected to a control panel. The local screen shows the concentration, while the selected output passes the alarm state to the external system. Before ordering, map the detector's 4-20mA, RS485, passive contact, or alarm interface to the input and action required by your control equipment.
JH-D operates from 220V AC, with maximum power consumption below 12W. The operating temperature is -20°C to 50°C, and operating humidity is 10% to 95% RH, non-condensing. Check the room temperature, humidity conditions, and available power at the intended mounting point.
A detector mounted in a damp utility area should be located where condensation is not expected. A site with temperatures outside the stated range needs a different equipment review. Include the ambient conditions in your request so we can assess the configuration with the sensor selection.
The 4.3-inch screen displays concentration, alarm, time, storage, and other information. JH-D automatically identifies and displays over-concentration, sensor short-circuit, and open-circuit faults. This helps the person checking the unit distinguish an alarm condition from a sensor circuit fault on the display.
Parameter setup uses an infrared remote control, and the design supports on-site alarm calibration without opening the enclosure. The plug-in sensor process supports on-site inspection and later maintenance. For procurement, include the selected sensor component, gas, range, and calibration arrangement in your inquiry.
Yes. JH-D supports RS485 with Modbus RTU and a 4-20mA current loop. This gives you a choice of digital or analog integration when planning the control architecture. The unit also includes one set of passive contacts and one audible/visual alarm interface, so include the receiving equipment and required alarm action in your connection plan.
The selectable gas categories include toxic gases, O₂, CO₂, and TVOC, with other gas choices available through sensor selection. The measuring range also depends on the selected sensor. Give us the exact gas name and required range, because the enclosure model alone does not identify the sensor configuration.
An infrared remote control handles parameter setup, and the design supports on-site calibration without unboxing the detector. This is useful when the unit is already mounted and accessible from the front. Include the required alarm settings and sensor information in your order discussion so the setup plan matches the selected gas.
Choose our JH-D Gas Detection Alarm (Standalone) when you need a single-circuit, non-explosion-proof wall-mounted detector with local display, configurable sensing, and 4-20mA or RS485 integration. Send the gas name, measuring range, area classification, ambient temperature and humidity, power supply, mounting dimensions, and output connections for a quote.
The company
Jiangsu Jihua Electronic Technology Co., Ltd. was established in 2007. It is a national high-tech enterprise specializing in the research and development, production, sales and service of gas and dust concentration detection alarm and environmental monitoring equipment. The products are mainly used in many fields such as petroleum, chemical industry, gas, medicine, metallurgy, machinery, factories and mines, grain processing, environmental monitoring, etc.…